Selection GuideWorkshop & machinery16 min read

Silica Gel, Drierite or Molecular Sieve in a Desiccator

Bower put silica gel at 0.030 mg/L and calcium sulfate at 0.005. Schultz measured the same pair 140 times apart. The EMD table puts them the other way round.

Updated November 14, 2026How Equipvia researches
Laboratory desiccators holding reagent bottles and chemicals, photographed on a bench
The desiccant is chosen for the residual humidity it holds, and the published figures for that differ by two orders of magnitude. Photograph via Wikimedia Commons (CC0). View image source.

Disclosure: We may earn a commission if you purchase through links on this page, at no additional cost to you. Our selection criteria do not depend on commission; see our affiliate disclosure.

Bower's 1934 survey gives silica gel 0.030 mg/L and calcium sulfate 0.005 mg/L, a ratio of 6.0. Schultz gives Drierite 0.000655 mg/L and silica gel 0.0919 mg/L, a ratio of 140. The EMD Millipore snippet gives silica gel 0.002 and calcium sulfate 0.07, a ratio of 35 with the order reversed. Three sources, one pair of materials, and every possible ranking.

Bower's paper is Research Paper RP649 in volume 12 of the Journal of Research of the National Bureau of Standards. His air ran through U-tubes at 30.5 ± 0.5 °C and 1 to 5 litres per hour in most runs, and he did not determine ultimate drying power or capacity.

What the 1934 NBS survey measured

Residual water at 30 °C, in mg per litre of air, in order of increasing efficiency: anhydrous CuSO₄ 2.8; granular CaCl₂ 1.5; technical anhydrous CaCl₂ 1.25; ZnCl₂ sticks 0.98; Ba(ClO₄)₂ 0.82; NaOH sticks 0.80; dehydrated granular CaCl₂ 0.36; Mg(ClO₄)₂·3H₂O 0.031; silica gel 0.030; KOH sticks 0.014; Al₂O₃ 0.005; anhydrous CaSO₄ 0.005; CaO 0.003; anhydrous Mg(ClO₄)₂ 0.002; BaO 0.00065.

Against calcium sulfate at 0.005, anhydrous CuSO₄ is 560 times worse, the trihydrate of Mg(ClO₄)₂ is 15.5 times the anhydrous salt, and granular CaCl₂ at 1.5 is 4.2 times the dehydrated form at 0.36. Barium oxide at 0.00065 is the best figure in the table, and it is the one material on the list that no desiccator in a teaching lab is likely to hold.

The preparation conditions matter as much as the material. Bower's calcium sulfate was made by heating the dihydrate at 220 to 230 °C for 2 hours, with a range of 0.004 to 0.009 mg/L. His alumina, sold as Hydralo, held about 11 percent water and needed 150 to 180 °C for 6 hours, because without that step its efficiency was very much lower. Phosphorus pentoxide served as the guard tube, and the paper gives no residual value for it or for sulfuric acid. His silica gel went through 110 to 130 °C in vacuo for 5 hours from 11.3 percent water, with a range of 0.02 to 0.04 mg/L.

Five sources, different rankings

Source Silica gel Calcium sulfate (Drierite) Basis
Bower 1934, NBS 0.030 mg/L 0.005 mg/L 30 °C, U-tube train
Hammond Drierite, as repeated by sellers not stated 0.005 mg/L, dew point −100 °F 25 to 30 °C, "verified by NBS"
Schultz, chilled mirror 0.0919 mg/L, frost point −39 °C 0.000655 mg/L, frost point −77 °C 40 % RH, 25 °C, 2.5 L/min
Industrial Monitor Direct blog dew point −40 °C below 0.002 mg/L at 25 °C air-drying guide
EMD Millipore snippet 0.002 mg/L 0.07 mg/L not shown; page redirected, row alignment unverified

Schultz's Drierite at 0.000655 mg/L is 140 times lower than his silica gel at 0.0919 mg/L. The EMD snippet's silica gel at 0.002 is 35 times lower than its calcium sulfate at 0.07. Bower's calcium sulfate at 0.005 is 7.6 times higher than Schultz's Drierite and 2.5 times higher than the Industrial Monitor Direct ceiling of 0.002. Bower's BaO at 0.00065 is within 1 percent of Schultz's Drierite at 0.000655. Bower's silica gel at 0.030 is 3.1 times lower than Schultz's at 0.0919 and 15 times higher than the EMD snippet's at 0.002.

Hammond's 0.005 mg/L at 25 °C is a frost point of −63.3 °C. Hammond's dew point of −100 °F is −73.3 °C, which is 0.00116 mg/L at 25 °C, 4.3 times lower. Schultz's 0.000655 mg/L is −76.9 °C against his stated −77 °C, and his 0.0919 mg/L is −40.1 °C against his stated −39 °C. Bower's 0.030 mg/L is a frost point of −49.6 °C at 25 °C, and the EMD snippet's 0.07 mg/L is −42.5 °C. These conversions are arithmetic on published vapour-pressure data, not published figures, and neither the Schultz nor the Bower paper gives enough detail to explain why their silica gel values differ by a factor of three.

A Texas A&M press-clipping file of a radiotracer study of water-saturated diethyl ether calls both sodium and calcium sulfate surprisingly ineffective for liquids, so the ranking in air does not carry over to solvents. Williams and Lawton (J. Org. Chem. 2010, 75, 8351) used coulometric Karl Fischer titration in a glovebox for solvents, and list Bower 1934 and Trussell and Diehl (Anal. Chem. 1963, 35, 674) among the gas-drying precedents.

Capacity figures that do not share a basis

Drierite, from the manufacturer's data as repeated by Fisher, Cole-Parmer and Sigma-Aldrich pages: 6.6 weight percent for drying liquids, forming the hemihydrate, and 10 to 14 weight percent for gases, because the granules have 38 percent pore space. Cole-Parmer lists the indicating grade at 10 to 14 percent and the non-indicating grade at 6 percent. Sorbent Systems lists calcium sulfate at up to 10 percent. An Occidental Chemical solvent-drying table lists 5 to 6 percent. Schultz lists 5.6 percent at 33 % RH and 4.9 percent at 11 % RH, on a volume basis.

Silica gel capacity: 40 percent of weight at Sorbent Systems, 38 percent at MDS Associates, 8.9 percent by volume at 33 % RH and 2.9 percent at 11 % RH in Schultz's test, and 4.6 percent at 10 % RH in the IMPAK QA Lab data that Sorbent Systems reports. Molecular sieve capacity: 19.8 percent at 10 % RH, 20 percent at MDS Associates, 20 percent for 3 Å and at least 21 percent for 4 Å at Streampeak, and 14 to 18 percent loaded in Merck's example of 250 g drying more than 10 litres of hydrophobic solvent.

At 10 % RH the molecular sieve loading of 19.8 percent is 4.3 times the silica gel loading of 4.6 percent. Silica gel at 40 percent is 8.7 times its own 4.6 percent loading, and Schultz's 8.9 percent at 33 % RH is 3.1 times his 2.9 percent at 11 % RH. Sorbent Systems gives 1 % RH as the floor for molecular sieve and around 40 % RH for silica gel in a container. None of the capacity figures comes with a single shared humidity, so the list cannot be ranked from one column.

Residual water as relative humidity

Saturation is 22.98 mg/L at 25 °C and 30.28 mg/L at 30 °C. Bower's 0.030 mg/L is 0.099 % RH, 0.005 is 0.017 % RH, 0.002 is 0.0066 % RH and 1.5 is 5.0 % RH. Schultz's 0.0919 is 0.40 % RH and 0.000655 is 0.0029 % RH. The EMD snippet's 0.07 is 0.30 % RH and its 0.002 is 0.0087 % RH. Room air is 11.49 mg/L at 25 °C and 50 % RH, 8.72 mg/L at 22 °C and 45 % RH, and 13.79 mg/L at 25 °C and 60 % RH. Bower's 0.099 % RH is 505 times below 50 % RH. All of these are arithmetic, not published conversions.

What one opening costs

Take an assumed 6 L of air in the chamber. At 25 °C and 50 % RH a complete air exchange brings in 69 mg of water. A 100 g charge holds 6.6 g at Drierite's 6.6 percent liquid figure, 10 g at 10 percent and 14 g at 14 percent. Dividing by 69 mg gives 96, 145 and 203 complete exchanges. Using Sorbent Systems' loadings at 10 % RH, 100 g of silica gel holds 4.6 g, which is 67 exchanges, and 100 g of molecular sieve holds 19.8 g, which is 287 exchanges. Real openings exchange only part of the air, so these are upper bounds on how fast the charge is used.

For a 3 L chamber the exchange brings in 34.5 mg, and 100 g of charge gives 191, 290 and 406 exchanges for Drierite at 6.6, 10 and 14 percent, 133 for silica gel and 574 for molecular sieve. For a 10 L chamber the water is 114.9 mg per exchange and the counts are 57, 87, 122, 40 and 172. Between 3 L and 10 L the counts fall by a factor of 3.3 for every charge. At 22 °C and 45 % RH a 6 L exchange brings in 52.3 mg, which is 24 percent less than at 25 °C and 50 % RH, and 100 g of charge gives 126 exchanges for Drierite at 6.6 percent, 88 for silica gel and 378 for molecular sieve.

Regeneration temperatures

Hammond's regeneration instruction for indicating Drierite is 1 hour at 210 °C (425 °F). The 210 °C is 410 °F and the 425 °F is 218.3 °C, a gap of 8.3 K inside one sentence. Fisher lists 210 to 220 °C for 1 hour. Commercial and Du-Cal grades are listed at 450 °F (232 °C) for 2 hours. Under vacuum the data list 26 inches Hg at 325 °F (163 °C) or 28 inches Hg at 275 °F (135 °C). The window from 210 to 232 °C is 22 K wide. Bower used 110 to 130 °C in vacuo for 5 hours for silica gel and 150 to 180 °C for 6 hours for alumina. The EMD snippet lists 150 to 250 °C for silica gel and 190 to 230 °C for calcium sulfate. Industrial Monitor Direct lists 232 to 316 °C (450 to 600 °F) for molecular sieve.

Bower's 30.5 °C cabinet is 86.9 °F. His silica gel at 110 to 130 °C is 230 to 266 °F, his calcium sulfate at 220 to 230 °C is 428 to 446 °F, and his alumina at 150 to 180 °C is 302 to 356 °F. The EMD snippet's 150 to 250 °C is 302 to 482 °F and its 190 to 230 °C is 374 to 446 °F. The vacuum temperatures of 163 °C and 135 °C are 47 K and 75 K below 210 °C. Hammond's vacuum readings of 26 and 28 inches Hg are 88.0 and 94.8 kPa, which leave 13.3 and 6.5 kPa absolute if they are gauge readings; that the numbers are gauge is an assumption, not something the sheet states.

Equipvia may earn a commission from qualifying purchases through this link. The link resolved to Product ID 1600795884229 during review. CPS resolution does not verify the seller's technical claims, the capacity, affiliate eligibility, or commission attribution. Check the actual selected variant and current terms before ordering.

The capacity column is where this purchase is won or lost, and a sieve listing usually omits it. The figures above run from about 14 to 21 percent depending on the source and the humidity, against 2.9 to 4.6 percent for silica gel at the same low humidity, so the sieve is the better charge for a cabinet that is opened often. What the listing does not say is the capacity at the humidity your desiccator actually sits at, the amount of water already in the beads as shipped, or the regeneration temperature and gas atmosphere the maker expects. Ask for those three, and note that a bag sold for ethanol drying may arrive with enough residual moisture that the first charge does very little.

The indicator is a regulatory problem

Fisher lists indicating Drierite at 98 percent CaSO₄ and under 2 percent CoCl₂, so up to 2 g of CoCl₂ in 100 g. The Carc. 1B specific concentration limit of 0.01 percent is 200 times below 2 percent and 100 times below 1 percent. The Hammond sheet lists chlorine release at 318 °C, which is 86 K above 232 °C. Cobalt dichloride has the CAS number 7646-79-9 and the EC number 231-589-4. The hazard entries on the indicating silica gel sheets are Carc. 1B H350i, Repr. 1B H360F and Muta. 2 H341.

France submitted the Annex XV dossier on cobalt dichloride on 2 June 2008. Productip dates the candidate-list status to October 2008, which is 18 years before 2026. The dossier lists the uses as humidity indicators in hygrometers, barometers and self-indicating silica gels, the manufacture of vitamin B12 and the addition of cobalt to food and feed. One ACS-grade sheet lists silica at 99.50 percent, other sheets list cobalt chloride under 1 percent, and a cartridge sheet lists up to 2.5 percent.

Granule size follows the same pattern of loose description. Fisher lists Drierite in 4, 8 and 10 to 20 mesh. On ASTM E11 sieve openings, No. 4 is 4.75 mm, No. 8 is 2.36 mm, No. 10 is 2.00 mm and No. 20 is 0.850 mm, so the 4 mesh opening is 2.0 times the 8 mesh opening and 5.6 times the smallest opening of the 10 to 20 grade. The 2011 Hammond sheet hosted by Purdue lists calcium sulfate at 15 mg/m³ for the OSHA PEL and 10 mg/m³ for the ACGIH TLV, a ratio of 1.5, and a solubility in water of 0.25 g per litre. The EMS sheet lists cobalt dichloride at 0.13 mg/m³ for PAC-1 and 83 mg/m³ for PAC-2, a ratio of 638, and amorphous silica at 18 mg/m³ for PAC-1, which is 138 times the cobalt dichloride value.

Choosing by the job

By loading at about 10 % RH, the order from these sources is molecular sieve at 19.8 percent by mass, then Drierite at 4.9 percent by volume at 11 % RH, then silica gel at 2.9 percent by volume at 11 % RH or 4.6 percent by mass at 10 % RH. The bases differ, so that order is judgment, not a published ranking. Per 100 g the full-exchange counts are 287 for molecular sieve, 96 to 203 for Drierite and 67 for silica gel.

For a desiccator that is opened daily, molecular sieve uses its capacity best and holds the lowest humidity. For a cabinet that stays shut, the difference in capacity matters less than the residual humidity, and there the sources disagree enough that the honest answer is to measure with a hygrometer in your own chamber. For solvents, none of this applies: Williams and Lawton cover that case, and the gas-phase order does not transfer.

What this article could not check

The EMD Millipore table was seen only as a snippet, with the page redirected and the row alignment unverified, so its reversed ranking is reported and not relied on. Schultz's report was not available beyond the figures quoted in the secondary sources, and the Bower and Schultz silica gel values cannot be reconciled from what those sources print. The sample sizes behind the BioLife and Schultz numbers are not stated. Trussell and Diehl 1963 was not read. Capacity figures differ in basis between mass and volume and between humidities, so the ranking in the choosing section is a judgment built on those figures rather than a published conclusion.

Share this article

View all guides